Products: Transducers
Control Interface Transducers
  • Direct connection to PCs
  • Easily accessible wiring terminal blocks
  • Quick panel mounting with supplied snap-track
  • Floating point and pulse width modulation options
  • Input signal and power supply protection
  • AC/DC operation
  • Feedback signals available
  • Signal generators
  • High accuracy
  • Lighting controls

GT-AI420Loop-powered Analog Input with Optical Isolation to Analog Output

SpecificationsInstallation

GT-AI420: The GT-AI420 transducer is a 2-wire loop-powered 4-20 mA signal isolator with one input/output channel. It will accept one analog, current or voltage, input signal, isolate it and sink a current output signal. The input has several fixed ranges for various
applications.
Read More


GT-AIAnalog Input with Optical Isolation to Analog Output (Re-scales & Limits Output)

SpecificationsInstallation

GT-AI: The GT-AI transducer is a 3-way isolating analog signal re-scaling module with one input/output channel. It will accept an analog voltage or current input signal, isolates it and re-scales it to another voltage or current output signal. The I/O signals have several pre-calibrated, fixed ranges or may be custom calibrated for various offsets and spans and can be direct or reverse acting to provide signal inversion.
Read More


GT-ARAnalog to Two or Four High and Low Trip Level Relay Outputs
                        AR2                       AR4
SpecificationsAR2 InstallationAR4 Installation

GT-AR: The GT-AR series analog to relay module accepts an analog voltage or current signal and controls either 2 relays (GT-AR-2) or 4 relays (GT-AR-4). The input signal has three jumper selectable ranges for either 0-7.5 Vdc, 0-15 Vdc or 0-20 mA. Each relay has an independently adjustable setpoint which is set with a multi-turn pot.
Read More


GT-ARESAnalog to Resistance Output

SpecificationsInstallation

GT-ARES: The GT-ARES transducer is an interface that accepts a DIP switch selectable analog input (voltage or current) and uses that signal to proportionally control a variable resistance output. The device output simulates a three-wire slide wire or rotary
potentiometer and has both ends of the potentiometer and the wiper available on a terminal connector. The resistive output is electrically isolated from the input signal.
Read More


GT-ASMAnalog Current or Voltage Rescaling Module

SpecificationsInstallation

GT-ASM: The GT-ASM transducer is used for analog signal conversion or re-scaling. It will accept one DC voltage, current or resistive input signal and output a non-isolated voltage or current signal. The output signal is easily calibrated for various offsets and spans and can be direct or reverse acting to provide signal inversion.
Read More


6N1 - ISOSix Analog Input to Average, Lowest, Highest, or Difference Analog Output

SpecificationsInstallation

6N1 - ISO: The 6N1-ISO is a microprocessor controlled interface designed to provide maximum flexibility with a minimum of cost. The 6N1-ISO can average two to six inputs, output the highest of two to six inputs, output the lowest of two to six inputs or output the difference of two inputs.

AFPAnalog to Floating Point Output

SpecificationsInstallation

AFP: The AFP allows an analog signal to control a floating point actuator. It allows an analog signal to generate two digital outputs (Increase/Decrease). The AFP's isolated floating point output can be controlled by several analog input signal ranges.





ARM2Analog Current or Voltage Rescaling Signal Splitter

SpecificationsInstallation
 
ARM2: The ARM2 will accept a single analog voltage or current signal and split that signal into two DC non-isolated current sourcing outputs that can be re-scaled. Its primary application is as a signal splitter. The outputs are always scaled identically and will always track each other.

ASAAnalog Signal Amplifier

SpecificationsInstallation

ASA: The ASA is an analog signal amplifier which accepts an analog voltage or current signal and outputs a voltage signal. Several preset input ranges are jumper selectable. ASA is designed to give a Building Automation System signal output the power (wattage) to control MaxitrolTM gas valves normally installed in rooftop units.

ATPAnalog Current or Voltage to PWM[1] Output

SpecificationsInstallation

ATP: The ATP converts an analog signal into a digital pulse output signal. The user can select eight standard analog input ranges to the ATP by changing jumper shunt positions. To select the output pulse range, the ATP has an eight position DIP switch. The output pulse is continuous with a one second off between pulses.

AUDFloating Point to Analog Output

SpecificationsInstallation

AUD: The AUD converts a floating point signal into a linear analog output. There are two inputs on the AUD, one to increase the analog output and one to decrease the analog output. The output of the AUD is stable when the inputs are both off. The output of the AUD is in the form of an analog, steady state voltage or current.

DMUXPWM[1] Input to 4 or 8 Addressable Relays

SpecificationsInstallation

DMUX: The DMUX is a selectable output controller designed to expand the output capacity of an energy management or process controller. The DMUX has either 4 or 8 output relays which can be individually addressed by a single pulse width modulated input signal.

DRN4Analog, Floating Point, & PWM[1] to Proportional Resistance Output

SpecificationsInstallation

DRN4: The DRN4 is a resistive output motor actuator interface that accepts several types of DDC system signals. The DRN4 output is 0 to 135 ohms. The input signal types are field selectable by an 8-position DIP switch. The DRN4 is supplied in an enclosure that can be directly mounted to a ฝ inch knockout on the motor actuator.

MAODual Analog Voltage/Current Adjustable Manual Override

SpecificationsInstallation

MAO: The MAO installs between a controller and an actuator to provide an adjustable analog manual override when needed. In normal operation two (2) analog signals can be routed from the controller through the MAO to each actuator.

MDO2FSTwo Channel Digital Manual Override (Maintained)

SpecificationsInstallation

MDO2FS: The MDO2FS is designed to be installed between a controller and an actuator to provide manual override when needed. In AUTO operation up two (2) digital signals can be routed through the MDO2FS from the controller(s) to each actuator.

PSGProgrammable Signal Generator

SpecificationsInstallation

PSG: The PSG is a hand held programmable signal generator designed to simulate analog or pulse signals from controllers, sensors, and other building automation system components. It is designed as an aid to speed up the process of system setup and calibration. PSG is equipped with a removable cable with alligator clips for power and signal attachment.

PTAPWM[1] to Analog Current or Voltage Output

SpecificationsInstallation

PTA: The PTA converts a single pulse-width modulated input to an analog current or voltage output. A timed contact or solid state closure from the controlling microprocessor controller is converted to a linear analog output signal with 256 steps of resolution.

PTA2PWM[1] to Analog Current or Voltage Output

SpecificationsInstallation

PTA2: A timed contact or solid state closure from the controlling microprocessor controller is converted to a linear analog output with 255 steps of resolution. Four input pulse rates are jumper selectable. The PTA2 includes triac adapter circuitry (jumper selectable) for a triac input.

RTIRTI Resistance to Analog Output

SpecificationsInstallation

RTI: The RTI converts a 3-wire resistance signal to an analog output, using current loop power (two wire). The RTI is reverse polarity protected and offers linear tracking of a 3-wire resistance input against the standard output signal of a 4 to 20 milliamp (current source).

PHOTON4.1Lighting Control Interface via RS485 bus or digital input

SpecificationsInstallation

PHOTON4.1: The PHOTON4.1 interface has 4 outputs capable of controlling G.E.ฎ RR7 or RR9 relay types (up to 10 per output) or Schlage Electronicsฎ or TOUCH-PLATEฎ 3000-PL relay type lighting contactors. It provides the necessary latch and unlatch pulses required by these contactors.

TOBPulse to Pulse Output (Triac amplifier)

SpecificationsInstallation

TOB: The TOB will accept up to two separate signals from up to two AC TRIAC outputs, or DC sources, and provide up to two TRIAC outputs each capable of driving a 2.5A load. Each output TRIAC is activated for the time that the signal is applied to the input.

NOTES: [1] PWM - Pulse Width Modulated *Different models available

 
Tip of the Month
CO2 Sensor Coverage:
How many sensors are required in a typical installation and where should they be located?

Technical Tidbit
Product Linecard
Download our Product Linecard
to see an overview of our line
of HVAC Sensors and Transducers

Product Linecard
How do I order?Request a quoteNeed support?
Website designed and developed by Connetik Interactive