Products: Pneumatic

Electronic to Pneumatic Transducer

ETP-9500Electronic to Pneumatic Transducer

SpecificationsInstallation

ETP-9500: This unit installs between the controller and a pneumatic device. It offers a low cost alternative for retrofit or new construction installations. It is available in 4-20ma and 0-10vdc 2wire or 3 wire versions, with or without an enclosure.
Read More



Pneumatic Transducers

FEATURES
  • Direct connection to PCs for pneumatic control
  • Three-wire voltage modes and current ouptuts
  • Easily accessible wiring terminal blocks
  • Quick panel mounting with supplied snap-track
  • Floating point and pulse width modulation options
  • High accuracy with low hysteresis
  • Manual override available as standard or optional
  • Drifless operation with high repeatability
  • Input signal and power supply protection
  • AC/DC operation
  • Air filter supplied
  • Feedback signals available

ENC1Enclosure

SpecificationsInstallation

ENC1: Protects transducers or any automation or HVAC component. Twenty gauge metal, 2" diameter opening in cover for guage, two 7/8" diameter openings in the base ends for 1/2" EMT fitting for wiring connection, plastic snap-in covers for all openings.Size: 3.05" W x 3.3" H x 6" L.
Read More


EFP*Floating Point to Pneumatic Output
 EFP:
EFP2/EFP2FS:
SpecificationsInstallationInstallation

EFP*: Input: Two Digital (relay, triac, or transistor) 9-24 VAC/VDC. Output: Jumper selectable 0 - 10, 0 - 15, or 0 - 20 psig air pressure. Rate of Change: 30, 45, 60, 90 sec., 2, 3, 6, and 8 minutes. Manual Override. Power: 24 VDC or 24 VAC @ 4A. Size: 4.0" L x 3.45" W x 1.875" H. Anodized aluminum manifold.
Read More


EPC* (Shown with optional gauge)Analog to Pneumatic Output
 EPC:
EPC2/EPC2FS:
SpecificationsInstallationInstallation

EPC*: Input: 0-5, 0-10 or 0-15 VDC/Infinite ohm, or 4-20 mA/250ohm. Output: 0-20 psig. Feedback: 0-5 VDC= selected output. Power: 24 VAC or VDC (50/60 HZ) @ 160 mA. Valve exhaust (EPC2), bleed-type in 41 scim (EPC), & dual Fail-safe (EPC3FS). Aluminum manifold. Gauge Optional
Read More


EPCBAnalog to Pneumatic Output

SpecificationsInstallation

EPCB: Input: 0-5, 0-10 or 0-15 VDC/Infinite ohm, or 4-20 mA/250ohm. Output: 0-10, 0-15 and 0-20 psig. Feedback: 0-5 VDC= selected output. Power: 24 VAC or VDC (50/60 HZ) @ 180 mA. Controlled exhaust dual valve. Fail-safe model EPC2GFSB. Aluminum manifold. Rugged painted metal housing.
Read More


EPW*Pulse Width Modulated to Pneumatic Output
 EPW:
EPW2/EPW2FS:
SpecificationsInstallationInstallation

EPW*: Input: 0.1 - 10, 0.02-5, 0.023-6 or 0-10 sec. Duty cycle, 0.59 - 2.93, 0.1 - 25.5 sec. or 0 - 20 V phase cut. Trigger: 9 - 24 VAC/VDC. Output: 0 - 10, 0 - 15, 0 - 20 psig Manual override. Feedback: 0 - 5 VDC = range. Power: 24 VDC or 24 VAC @ 160mA. Valved exhaust or bleed type at 14, 41 & 73 scim, & Fail-Safe model
Read More


MPOEManual Pneumatic Override/Electric

SpecificationsInstallation

MPOE: Installs between controller and actuator to provide manual override in case of controller malfunction or during system checkout. PRV, terminal strip, switch and pneumatic connections mounted in twenty gauge metal bracket.
Read More


PTP100100 psig Pressure to Analog Voltage or Current Output

SpecificationsInstallation

PTP100: Input: 20 - 100 psig air pressure. Output: 1 - 5 VDC, 2 - 10 VDC, 3 - 15 VDC, & 4 - 20mA @ 750 ohm load impedance. Power 24 VAC or 24 VDC @ 50mA max. Size: 3.75" L x 2.25" W x 1.5" H. Brass barbed fittings in anodized aluminum manifold.
Read More


PTPPressure to Analog Voltage or Current Output

SpecificationsInstallation

PTP: Input: 3 - 15, 3 - 30 or 0 - minus 7.5 psig air pressure. Output: 1 - 5 VDC, 2 - 10 VDC, 3 - 15 VDC, & 4 - 20mA @ 750ohm load impedance. Power: 24 VAC or 24 VDC @ 50mA max. Size: 3.75" L x 2.25" W x 1.5" H. Aluminum silver anodized manifold. Gauge available.
Read More


PTS4.1Floating Point to Pneumatic Output

SpecificationsInstallation

PTS4.1: Input: Two Digital (relay, triac, or transistor). Output: 0 - 10, 5 - 15, or 0 - 15 psig air pressure (jumper selectable). Rate of Change: 90 seconds. 1% Accuracy at room temperature. Power: 24 VDC or 24 VAC @ 4 VA. Size: 3.25" L x 2.25" W x 1.5" H. Anodized aluminum manifold. Gauge optional.
Read More


PXP100Analog to 100 psig Output

SpecificationsInstallation

PXP100: Input ranges/impedance: 0 - 5 VDC, 0 - 10 VDC or 0 - 15 VDC/10 Kohm, or 0 - 20mA/250 ohm. Output: 0 - 100 psig. Feedback: 0 - 5 VDC= 0 - 100 psig. Power: 24 VAC or VDC @ 150mA. Size: 3.25" L x 2.25" W x 1.5" H. Valved exhaust, anodized aluminum manifold.
Read More


NOTES: [1] PWM - Pulse Width Modulated *Different models available

 
Tip of the Month
CO2 Sensor Coverage:
How many sensors are required in a typical installation and where should they be located?

Technical Tidbit
Product Linecard
Download our Product Linecard
to see an overview of our line
of HVAC Sensors and Transducers

Product Linecard
How do I order?Request a quoteNeed support?