Products: Current

Current Switches

CS SeriesAC Mini Current Switch - Solid Core
 CS610M:CSGnGM:
SpecificationsInstallationInstallation

The CS Series mini current switch monitors line current for electrical loads such as pumps, conveyors, lighting, heaters or fans and closes the output contacts when the trip point is exceeded. The CS-GnG-100 has a factory set trip point of 0.5 Amps to provide Go/No Go status operation. The CS-610-75 has a trip setpoint that is adjustable between 0.75 to 75 Amps by rotating the adjustment knob.
Read More


CS SwitchAC Current Switch - Solid Core
 CS610:CSGnG:
SpecificationsCS610 InstallCSGNG Install

The CS Series current switch monitors line current for electrical loads such as pumps, conveyors, lighting, heaters or fans and closes the output contacts when the trip point is exceeded. The CS-GnG-200 has a factory set trip point of 0.75 Amps to provide Go/No Go status operation. The CS-610-200 has a trip setpoint that is adjustable between 1 to 200 Amps by rotating the adjustment knob.
Read More


AC Current Switch - Split Core

                                        SC610:                   SCGnG:
SpecifictaionsInstallationInstallation

The SC series of Split-Core AC current switches are solid-state switches that activate a contact closure whenever the monitored primary circuit current exceeds a pre-set level. Several models are available to switch various load types. Models feature integral LEDs to indicate device power and also the switch status.
Read More


AC High Current Switches

                                        CS425               CS325/SC525  
SpecificationsInstallationCS325-SC525 Installation - PDF - 73Kb

Directly control AC loads, such as relays, lamps or fans, in response to the current of a monitored AC circuit
Read More


Current Sensors

CS-6XX-XX SeriesAC Mini Current Sensor - Solid Core
 CS650M:
CS651M:
CS652M:
SpecificationsInstallationInstallationInstallation

The CS-6XX-XX series of mini current sensors monitor line current for electrical loads such as pumps, conveyors, machine tools or fans and provide an output of 4-20 mA, 0-5 Vdc or 0-10 Vdc (Model specific) to represent the load current.
Read More


CS Current SensorAC Current Sensor - Solid Core
  CS650B CS651B
 Specifications CS650 Installation CS651 Installation
  CS652B CS675B
  CS652 Installation CS675 Installation

The CS-6XX-XX series of current sensors monitor line current for electrical loads such as pumps, conveyors, machine tools or fans and provide an output of 4-20 mA, 0-5 Vdc or 0-10 Vdc (Model specific) to represent the load current.
Read More


AC Current Sensors - Split Core
 SC650
SC651
SpecificationsSC650 Installation SC651 Installation

SC652
SC675

SC652 InstallationSC675 Installation

The SC6XX-XX series of split-core current sensors monitor line current for electrical loads such as pumps, conveyors, machine tools or fans and provide an output of 4-20 mA, 0-5 Vdc or 0-10 Vdc (Model specific) to represent the load current.
Read More


Command Relay

SpecificationsInstallation

CSR-112/CSR-124: Command Relays are line voltage relays for use with the CS and SC current sensors and switches.
Read More


CVT-100CT/PT Input Transducers

SpecificationsInstallation

CVT-100: Power consumption monitoring and overload detection.
Read More



Accessories

Model A3504Model A3504 Switch

Specifications

This Switch Assembly is designed to provide a disconnecting means for your watt transducer.Not only can this Switch Assembly provide isolation from line voltages, it also will short out current transformer secondaries, adding considerable safety against high potential electrical shock from live open CTs.The bottom side of the switch is connected to the circuits being measured. The top side of the switch is connected to the watt transducer. The switch handles are colour coded red for voltage and black for current. The black plastic cover is constructed so that all switches must be in the closed position before the cover can be sealed.

Model RLSolid Core Current Transformers

Specifications

Model RL: These solid core Current Transformers are available in two sizes and a wide range of current ratios.

These Current Transformers provide a low amperage current output proportional to line current, for use in building automation, relaying, or metering. The core and windings of each unit are completely encased in UL approved plastic that is rated 94V1, and there are no exposed metal parts other than the terminals.

Model 601TSplit Core Current Transformers

Specifications

Model 601T: These split core Current Transformers are designed to be assembled around an existing (insulated) conductor without the need for dismantling the primary bus or cables. The portion of the transformers marked "THIS END REMOVABLE" can be disassembled and then reassembled around the conductors that require current monitoring.


 
Tip of the Month
CO2 Sensor Coverage:
How many sensors are required in a typical installation and where should they be located?

Technical Tidbit
Product Linecard
Download our Product Linecard
to see an overview of our line
of HVAC Sensors and Transducers

Product Linecard
How do I order?Request a quoteNeed support?
Website designed and developed by Connetik Interactive